It’s a sterilizer that uses the dual effects of microwave and high-pressure steam to sterilize biohazardous Waste.
Treatment capacity appr. 2kg/hr. Perfectly suited for disposing of medical waste in medium or small sized hospitals, clinics or any health centre, Customs and Quarantine Departments, etc.
Specifications:
Is a Microwave Medical Waste Disposal Unit that uses the dual effects of microwave and high pressure steam to sterilize Regulated Medical Waste (RMW), or medical waste with infection risk.
Treatment capacity: appr. 2kg/hr (based on an average density of medical waste at 0.1kg/l ~0.15kg/l.)
Sterilization bin volume: 30L
The disposal unit first introduces high-pressure saturated steam into the high-pressure disinfection chamber of medical waste, while starting a microwave generator. It uses the thermal effect of microwave to heat the high-pressure disinfection chamber to maintain temperature and prevent steam condensation. It is sterilized by the sensitivity of bacteria to temperature. In addition, microwave has a non-thermal effect, Non thermal effect refers to other microbial killing effects besides thermal effect, which is a unique effect of microwave sterilization. The heating and warming process of the equipment is also a disinfection process. After the disinfection chamber reaches 135 ℃ or above, it is held for another 5 minutes to complete the disinfection.
Model. | MMDU-30 |
Main unit body Dimensions | 634mm*503mm*749mm |
Overall weight | 110kg |
Treatment type | High temperature steam and Microwave sterilization |
Type of process | Semi-automatic process |
Chamber volume | 30 Liter |
Control | Simple button operation |
Sterilization temperature | ≥ 135℃ |
Pressure | ≥ 0.33MPa |
Sterilization cycle | ≥ 30 minutes |
Installed power | 3.5 Kw |
Utility Requirements | Electricity: 220V |
Treatment capacity * | 17L/cycle, or appr. 2 kg/hr (±10%) |
Staff requirements | No specialized operator / 1 operator |
Exhaust gas treatment system | Included |
Disposal section material | 304 stainless steel |
Microwave frequency | 2450 +/- 50 MHz |
Microwave generator power | 1.25kW |
Treatment effect | 6 log 10. The treatment effect test uses Bacillus subtilis var. niger spore (ATCC 9372) as biological indicator, with killing logarithm value ≥ 6.00. |
With a 'parameter printer' built into the machine that can track cycle data such as hospital name/operator name/cycle time/weight/cycle status. |
The processing scope of the equipment includes infectious, injurious, and pathological waste in the category of Biohazardous Waste.
*Do not put containers in a sealed state into the equipment.
High pressure steam and microwave combination disinfection, the disinfection process only takes 5 minutes, high disinfection efficiency, energy saving;
Using a water cooled microwave generator, the cooling medium is antifreeze, with a long service life;
The door of the microwave disinfection equipment adopts a conductive sealing strip sealing structure and is equipped with an interlocking system to prevent microwave leakage;
The disinfection chamber is made of 304 stainless steel, it is durable.
Equipped with an exhaust gas treatment device, including a high-efficiency filter and an activated carbon filter, the high-efficiency filter is used to treat microorganisms contained in the exhaust gas, with a filter particle diameter of 0.2 μ m. It can filter out almost all microorganisms, and activated carbon filters are used for deodorization.
Compare technologies |
LiYing Technology |
Autoclave |
Autoclave with a shedder |
Incinerator |
(Microwave) |
(Hot steam) |
(Hot steam) |
(Incineration) |
|
Continuous process |
✓ |
X |
X |
X |
Integral shredding |
✓ |
X |
✓ |
X |
Unrecognisable waste |
✓ |
X |
✓ |
✓ |
Volume of waste reduction |
✓ |
X |
✓ |
✓ |
Mass of waste reduction |
✓ |
X |
X |
✓ |
Installation requirements |
Low |
High |
High |
High |
Complexity of the installation |
Low |
Intermediate |
Intermediate |
High |
On-site installable |
✓ |
✓ |
✓ |
X |
Technology approval by countries all over the world |
High |
Intermediate |
High |
Low |
Level of sterelization |
High |
Intermediate |
High |
High |
Odours |
Low |
High |
Intermediate |
Intermediate |
Noise |
Low |
Intermediate |
Intermediate |
High |
Treatment of pathological and anatomical waste |
✓ |
X |
✓ |
✓ |
Cost |
||||
ROI |
High |
Low |
Low |
Low |
Investment costs |
Intermediate |
Low |
Intermediate |
High |
Operating costs |
Low |
High |
High |
High |
Maintenance costs |
Low |
High |
High |
High |
Labour costs |
Low |
High |
High |
High |
Environment |
||||
Impacts on the environment |
Low |
Intermediate |
Intermediate |
High |
Treated waste recyclable |
✓ |
X |
X |
X |
No contaminated rejection (such as water, steam) |
✓ |
X |
X |
X |
Security |
||||
No risk related to pressurized vessel |
✓ |
X |
X |
X |
Risk for workforce/personnel health |
No risk of toxic contaminants released into the air or the treated waste |
Intermediate |
Intermediate |
High |